Custom Tempest Filters |
||
Can’t find the correct part for your specific application?Let us design the exact solution to solve your problem. Our custom feedthrough solutions can be more cost effective than some of our competitor’s “catalog” items. ![]() |
Custom Tempest Filter Drawings |
|
Specifications |
||
| Voltage Rating | DC – 480 VAC | |
| Operating Frequency | DC – 400 Hz | |
| Visual/Mechanical | Per MIL-F-15733, paragraph 4.6.1 | |
| Capacitance | Per Mil-STD-202, Method 305 @ 1kHz | |
| Insulation Resistance | 1500 M |
|
| Dielectric Withstanding Voltage | > 500 VDC line-to-line & line-to-chassis per MIL-STD-202, Method 301 | |
| Insertion Loss | Per MIL-STD 220, see insertion loss limits per individual spec sheets | |
| Voltage Drop | Less than 1% of rated voltage per paragraph 4.6.8 of MIL-F-15733 | |
| Terminal Strength | Per MIL-STD-202, Method 211 | |
| Leakage Current | 5 mA maximum, measured per UL standard 1283 at 120 VAC, 60 Hz | |
| Voltage Discharge | Unit shall discharge to less than 30 VDC after removal or power | |
| Operating Temperature | -55° C to +71° C | |